Dryer ventpipes, properly calledvent ducts, come in a variety of materials. Mostdryer ductsare round and 4 inches in diameter. Some are flexible, and others are rigid. Because all types are sold for use with dryers, you would naturally assume that all are suitable for this application.

Get Price

Hot Products

News List

  • Federal Building Codes for Dryer Vents and Ducts Home

    Running corrugated plasticductsthrough the crawlspace may seem like a convenientventingsolution, but it doesn't comply with thecode.Section M1502 requires thatventsbe constructed of smooth...

    more
  • What is code for dryer vents

    Apr 04, 2020·Dryer ventingsystems are covered in the International ResidentialCode(IRC) at M1502 - ClothesDryer Exhaust.Here’s a summary of the requirements: • Dryers must be exhausted in accordance with manufacturer’s instructions (IRC M1502.1). •Dryer exhaustsystems must be independent of other systems and convey moisture to the outdoors.

    more
  • Installing a Dryer Vent to Code Requirements

    Since adryer ventis very important to prevent fire, many states around the country have strict rules and regulations when it comes to its installation. To help you install yourdryerbent tocoderequirements, here is what you should do.

    more
  • 2018 INTERNATIONAL RESIDENTIAL CODE CHAPTER 15

    Domesticdryer exhaust ductpower ventilators shall conform to UL 705 for use indryer exhaust ductsystems. Thedryer exhaust ductpowerventilatorshall be installed in accordance with the manufacturer’s instructions. M1502.4.5Duct length.

    more
  • Building Code Dryerbox

    A summary of the typicalcodesrelating thedryer ventingis as follows:Dryer vent systemsshall be independent of all other systems and shall convey the moisture to the outdoors. Terminations shall be a minimum of three feet from property line and 12" above the ground and not exhibit any type of screen.

    more
  • Dryer Venting Guidelines How to avoid dryer fire hazards

    Length of concealed rigid metal ducting shall not exceed 35 feet (25' for IRC). Deduct 5 feet from the allowable length for every 90 degree elbow and two and a half feet for every 45 degree fitting (the Dryer-Ell is an exception under 2006 IRC Section M1502.6, 2009 …

    more
  • Searchable platform for buildingcodes

    The maximum length of a clothesdryerexhaustductshall not exceed 35 feet (10668 mm) from thedryerlocation to the wall or roof termination. M1502.4.5.1 Specified Length The maximum length of the exhaustductshall be 35 feet (10 668 mm) from the connection to the transitionductfrom thedryerto the outlet terminal.

    more
  • VentingBuildingCode Dryer Ell

    In an effort to reduce the number ofdryerfires (over 15,500 per year in the US alone) most buildingcodehas strict guidelines for properlyventingadryer. Every foot ofductrun reduces airflow efficiency and small radius elbows have an even greater impact. TheDryer-Ell was specifically designed to …

    more
  • What is the maximum length for a clothes dryer vent

    Aug 18, 2018· Let’s start with what the IRC (International ResidentialCode) says: the maximum length of a straight run ofdryer ductis 35 feet, with a 5 foot deduction in length for each 90º bend and half that for 45º bends, based on using a 4-inch smooth metalvent, with no screws protruding into the air flow.

    more
  • Chapter 15 Exhaust Systems, 2010 ResidentialCodeof NY

    The maximum length of a clothesdryerexhaustductshall not exceed 25 feet (7620 mm) from thedryerlocation to the wall or roof termination. The maximum length of theductshall be reduced 2.5 feet (762 mm) for each 45-degree (0.8 rad) bend and 5 feet (1524 mm) for each 90-degree (1.6 rad) bend .

    more
  • Dryer VentSafety Installation Guide Clothes dryer vent

    Solid plasticdryer ductinstallations using 4" PVC piping, bulkier, joints require gluing, cut with a hand saw. Watch out: plastic piping might show up as adryer ventin some homes but it is notcode-approved and should not be used for this purpose. Like other clog-proneventmaterials this is an unsafe option. As Crnor elaborates:

    more
  • Multi family dryer venting The Building Code Forum

    Aug 16, 2018· Note, the end of your original post referred to Exception 1 of 714.4.1.1 and Exception 1 of 714.4.1.2. These do not apply to this installation. "conduits, pipes, tubes or vents" are notducts. "Vent" has a definition in the IMC. Starting with 2015 IBC, 717.6 referencesductsthat penetrate the ceiling membrane of a roof/ceiling assembly.

    more
  • One ofthe Biggest Building Code Offenders inthe Laundry

    Sep 12, 2017· Properventingmaterial: Acode-compliantdryer ventis constructed of a rigid pipe of nonflammable material with a smooth interior finish.The smooth interior inhibits lint buildup in grooves, and it is not easily crushed or broken. While buildingcodesdiffer around the country, twocode-compliantventmaterial options are solid aluminum pipe that is at least 0.4 millimeters thick or ...

    more
  • Can aDryer VentGo Up Through an Attic Home Guides

    The International ResidentialCodeallows you to run adryer ventthrough the attic, but you can't terminate it there. Doing so would fill your attic with warm, moist air that could rot the ...

    more
  • Lambro > Lambro Industries, Inc.

    Dryer ventingproducts that meet thecoderequirements for 2012 IMC - International MechanicalCode(Section 504.6.1) and 2012 IRC - International ResidentialCode(Section M1502.4.1) for Material and Size. NOTE:Venta clothesdryeraccording to the manufacturer's instructions and localcodes.

    more
  • Dryer VentInstallation and Upgrades (Video) (DIY)

    Pro tip: Use no more than 25 feet. of 4-inchduct, and subtract 5 feet for every 90-degree turn and 2 1/2 feet for every 45-degree turn fordryer ventinstallation. For example, adryerwith a 90-degree elbow at the exhaust port and another at the top of the basement wall can run a maximum of 15 feet.

    more
  • What's the Maximum Length Allowed for aDryer Vent

    Oct 02, 2012· The International ResidentialCode(IRC) states that the maximum length for adryer ventis 25 feet, according to the National Association of Certified Home Inspectiors website. However, there are a lot of variables that can enter into the equation.

    more
  • Installing a Dryer Vent to Code Requirements

    Installing a dryer ventin your house is very important. Without adryer vent, your basement can become covered with thick layers of lint that will not only make your basement look dirty, but …

    more
  • Common Sense Building Dryer Venting The HTRC

    Today’s buildingcodeshave gotten more stringent on this issue due to this issue. Sections M1502 (mechanical) & G2439 (Fuel Gas) of the IRC deal specifically withdryer venting. While the I-Codesare essentially drag & drop there is one small difference where G2439.5.5.1 calls for a maximum length of 35’ while M1502.4.4.1 calls for 25’.

    more
  • Can I Use PVC Pipe for MyDryer Vent

    Mar 13, 2014· Third, using PVC toventadryeris a violation according to most residential buildingcodes. Save yourself the stress / possible future agony and do it tocode. So What SHOULD I use? Always follow buildingcodesas to which materials to use / not to use. That being said, we recommend using a smooth rigid metalducttoventyourdryer.

    more
  • Dryer exhaust Fantech

    To calculate the length of your plannedductrun, measure from thedryerto the externalventingpoint in the roof or wall. For each bend or elbow add 5-7 feet to your totalductrun calculations (or as required by localcodes).

    more
  • How Long Should Your Dryer Vent LineBe Dryer Vent

    Long runs ofventline with multiple bends reduce the flow of air, often to the point where thedryerexhaust doesn't even reach the exhaustvent. The International ResidentialCode(IRC) SECTION M1502 CLOTHESDRYEREXHAUST guidelines states that adryerexhaustductshould not exceed 25 feet from thedryerto the exhaustventin the wall or roof.

    more
  • Run aVentBlockage test on your Samsungdryer

    Please share your ZIPCodeto find a nearby Best Buy location, our Samsung representative, wants to know about you so they can assist you better., our Samsung representative at Best Buy, want to know about you to set up a personal demonstration on your next galaxy device. ... TheVentBlockage test on yourdryerautomatically detects the status ...

    more
  • Appliance411 FAQ How long can mydryer ventbe

    Dryer VentingComparison Chart. The chart below shows the manufacturer recommendations** for maximumventlength under various conditions. The recommendations can change from model to model even on the same brand's products so consult the owner's manual or installation instructions for your specific model..Ventlength for vertical installations should likely be *considerably* less than the ...

    more
  • ClothesDryerVents The Proper and the Improper

    A home owner can take apart and clean thedryer vent’s interior himself. This is made easier with a vacuum cleaner with a long hose attachment. Some HVAC professionals and chimney sweeps also offerdryer ventcleaning as a service. During a home inspection, the inspector should try to determine the type of clothesdryer ventmaterial(s ...

    more
  • How to Properly Vent a Dryer(DIY) Family Handyman

    Ventdryers outside.Ventingthedryeroutside in cold weather wastes a lot of heat. To make the dyer more efficient, you can buy an inexpensive heat diverter and install it in the exhaustductof electric dryers only (not gas dryers).You’ll save about 50¢ worth of heat per load in the winter.

    more
  • Cana Dryer Vent Be Indoors

    Although adryer venttypically vents moist clothesdryerair into outdoor air, it is possible toventan electricdryerindoors.Gas dryers, by contrast, are required tovent dryerexhaust out of doors. The following are a few factors you should consider before choosing an indoordryer ventingsystem.

    more
  • Dryer VentCaps

    4-in Plastic Pest GuardDryer VentCap. Item #89145. Model #140157079002 ...

    more
  • 8Best Indoor Dryer Vent Lint Trap [2020 Buying Guide

    Apr 20, 2020· Thisdryer ventallows the excessive lint particles to be eliminated while ensuring the risks ofdryerfires are reduced to the maximum and that air can be passed through theductconveniently. It provides energy to thedryerwhile ensuring maximum functionality and reducing the …

    more
  • VentingtheDryerthrough theRoof DryerJack

    Terminating the shorterductrun with a DryerJack helpsventingthrough theroofdeliver on the promise this shorter route offers. At less than 5 1/2" above theroof…